Precast Concrete Plant

PHC slabs W:40 cm

Stressing wires  – W 6.35 mm

Stressing  strands  –  T 1/2”, T3/8”

Own weight
555 kg/m²
660 kg/m²

 

Geometric data and positioning of stressing strands

Positioning of stressing strands – fire resistance 120 min.

Type of PHC slab Distance from bottom – h (in cm) Distance from bottom h1 (in cm) Distance from bottom (in cm)
4.5 7.7 37.0
40068

6T 1/2”

2W 6.35
40078

7T 1/2”

2W 6.35
40088

8T 1/2”

2W 6.35
40098

8T 1/2”

1T 1/2”

2W 6.35
40108

8T 1/2”

2T 1/2”

2W 6.35
40118

8T 1/2”

3T 1/2”

3W 6.36

Geometric data

Composite w/5 cm topping Precast Amount Precast Unit
3056 2576
A(cm2)
699237 492195
I(cm4)
21.52 20.07
Y*(cm)
23.48 19.93
Yb(cm)
38.8 38.8
bw(cm)
21035 16224
Sx(cm3)

Useful loads table

Cross Section’s Ultimate Resistance
Key 28.4 tm/m
Type PHC slab 40068 T
32.73 tm/m
Type PHC slab 40078 T
37.02 tm/m
Type PHC slab 40088 T
40.79 tm/m
Type PHC slab 40098 T
44.5 tm/m
Type PHC slab 40108 T
48.2 tm/m
Type PHC slab 40118 T
700 2360
725 2160
750 1980 2370
775 1820 2180 2400 2480
800 1680 2020 2310 2390 2460
825 1540 1860 2180 2300 2370 2480
850 1420 1720 2020 2220 2290 2390
875 1310 1600 1880 2120 2210 2310
900 1210 1480 1740 1980 2130 2230
925 1120 1370 1620 1840 2060 2160
950 1030 1270 1510 1720 1920 2090
975 950 1180 1410 1600 1800 1990
1000 880 1090 1310 1500 1680 1870
1025 810 1020 1220 1400 1580 1750
1050 750 940 1140 1310 1480 1640
1075 690 870 1060 1220 1380 1540
1100 630 810 990 1140 1300 1450
1125 580 750 920 1070 1220 1360
1150 530 700 860 1000 1140 1280
1175 490 640 800 940 1070 1200
1200 440 590 740 870 1000 1130
1225 400 550 690 820 940 1050
1250 370 510 640 760 880 980
1275 330 460 600 710 830 920
1300 300 430 550 660 770 860
1325 270 390 510 620 720 800
1350 240 360 470 570 660 740
1375 210 320 440 530 620 690
1400 180 290 390 480 570 640
1425 150 250 360 440 530 600
1450 220 320 400 480 550
1475 190 290 370 440 510
1500 160 250 330 410 470
1525 220 300 370 430
1550 190 270 340 400
1575 160 230 300 360
1600 210 270 330
1625 180 240 300
1650 150 220 270
1675 190 240
1700 160 210
1725 190
1750 160
1775

 

Notes:

  1. The loads specified in the table consist of a constant 150 kg/m2 load + usage load
  2. The load specified in the table is the load beyond the PHC slab’s own weight and that of the complementary casting
  3. In the table, loads that are not in bold refer to PHC slabs whose total sinking from the topping date to the end of the crawl and contraction process is less than 350/L.
  4. The loads in bold refer to PHC slabs whose deflection from support level is less than 250/L
  5. Loads that are left of a thick line are based on the slabs’ shear strength