דלג לתוכן המרכזי
Font Size:
Site Colors:
Accesskey
S - Skip navigation
1 - Home page
4 - Search
Accessibility Statement
Precast Concrete Plant

Load tables and other technical information for the hollow slabs

Overview

Pre-stressed hollow core slabs for floors, ceilings and roofs of buildings. Solel Boneh’s precast concrete plant manufactures pre-stressed hollow core slabs 16, 20, 25, 30 and 40 cm-thick. Used to complete ceilings and/or fit the particular shape of a given ceiling, the slabs are custom-made to accommodate any size or angle. The slabs are manufactured using industrial control systems and state-of-the-art technologies, from the raw materials acceptance stage to the delivery of the finished product to the client. All processes are regularly controlled by the plant’s quality assurance system, which has been inspected by the Standards Institution of Israel and certified for ISO

 

Type of strand and/or wire

Unit

”T1/2

”T3/8

”W6.35

12.7mm

9.53mm

6.35mm

Proof breaking stress

mm²

1860

1860

1770

Elasticity module

mm²

195000

195000

200000

Initial load (To)

(טון)

13.2

7.2

4

Section area

mm²

98.71

54.8

31.7

Weight

(ק”ג/מ”א)

0.774

0.432

0.249

9001:2015 and the SSI 005 procedure and for labeling our products with the standard mark.

 

Explanations for the load tables

The PHC slabs’ load tables were prepared in accordance with the requirements of Israeli Standard SI 466, Parts 3 and 5.

 

Materials

  • Type of concrete the plate is made of – B-50.
  • The concrete’s strength at the time of release – 35 MPa.
  • Type of concrete required for casting – B-30.

 

Stressing steel

  • The stressing strands are T1/2”, or T3/8”, in accordance with IS 1735, Parts 1 and 4, and are of low relaxation.
  • 35W” wires, in in accordance with IS 1735, Parts 1, 2 for ???upper plate stressing

 

Load table

  • The load tables feature only useful loads. The weight of the prefabricated element and of the complementary casting, if any, have been taken into account.
  • Fire resistance: The 16, 20, 25, 30 and 40 cm-thick hollow core slabs are fire resistant for up to 120 minutes.

 

If you require any additional information, please contact the plant’s Technical Department.

 

Related projects

אתר זה אינו נתמך על ידי הדפדפן שלך אנא הורד גוגל כרום